50-400kW Overseas Integrated DC Charger Portfolio
Overseas integrated DC charger range with flexible power allocation, VIN recognition, configurable UI, and strong protection design.
Decision-ready product facts
Best fit
Integrated DC Charger
B2SmallB, B2B, Distributor
Buying route
This project product requires an inquiry and configuration review before payment.
Evidence and limits
Use the visible technical data and generated datasheet as the product evidence. Project-specific terms are confirmed directly during the inquiry process.
Source basis: Winline Technology Company Profile Manual (202604), pages 16-21, mapped to the current catalog record.
Key technical data
- Input
- 400Vac ±10% / 3P+N+PE / 45-65Hz
- Output
- 200-1000Vdc / CCS / CHAdeMO / GB/T
- Communication
- Ethernet / 4G / OCPP 1.6J
- Protection
- IP55
Models and configurations
| Model | Rated power | Dimensions (W x D x H) | Weight |
|---|---|---|---|
| YLUXD50KE | 50kW | 800 x 500 x 1935mm | ≤250kg |
| YLUXD60KE | 60kW | 800 x 500 x 1935mm | ≤250kg |
| YLUXD80KE | 80kW | 800 x 500 x 1935mm | ≤250kg |
| YLUXD120KE | 120kW | 850 x 610 x 2135mm | ≤330kg |
| YLUXD150KE | 150kW | 850 x 610 x 2135mm | ≤330kg |
| YLUXD160KE | 160kW | 850 x 610 x 2135mm | ≤330kg |
| YLUXD180KE | 180kW | 850 x 800 x 2135mm | 440kg |
| YLUXD240KE | 240kW | 850 x 800 x 2135mm | 440kg |
| YLUXD320KE | 320kW | 900 x 900 x 2285mm | 679kg |
| YLUXD400KE | 400kW | 900 x 900 x 2285mm | 679kg |
Bus depot and logistics hub: published high-power configuration record
The rows below are taken from the configuration list published on this page. The scenario column is an example question. It is used to locate the fields a buyer has to check. It is not a claim about site performance.
Published configuration by fleet scenario
| Example fleet scenario | Model code | Rated power | Cabinet record | What to verify against the site record |
|---|---|---|---|---|
| Depot where charging is concentrated in one overnight window | YLUXD50KE | 50kW | Dimensions (W x D x H) 800 x 500 x 1935mm · Weight ≤250kg | Check rated power and cabinet footprint against measured daily energy demand and bay area |
| Bus depot that charges in a daytime window and overnight | YLUXD150KE | 150kW | Dimensions (W x D x H) 850 x 610 x 2135mm · Weight ≤330kg | Check whether the published output range covers the vehicle charging voltage window |
| Long-haul logistics hub that needs the highest power at one site | YLUXD400KE | 400kW | Dimensions (W x D x H) 900 x 900 x 2285mm · Weight 679kg | Check transformer capacity and cable routing against published input supply and footprint |
Shared published record for every row above
- Input400Vac ±10% / 3P+N+PE / 45-65Hz
- Output200-1000Vdc / CCS / CHAdeMO / GB/T
- CommunicationEthernet / 4G / OCPP 1.6J
- ProtectionIP55
Boundary: this section lists only records published by Winline Technology on winlineglobal.com. It contains no third-party performance data and no supplier ranking.
Commercial routing
- AudienceB2SmallB, B2B, Distributor
- Lead timeProject schedule after site data
- ChannelRFQ / No Amazon listing
Buying questions
- Can this product be purchased online?
- Not as a standard checkout item. Submit an RFQ so configuration, delivery market and commercial terms can be reviewed.
- Where can specifications be verified?
- Use this product page and its generated datasheet. Both are generated from the same current catalog record.
- Are certifications guaranteed for every market?
- No. A certification is displayed only when a certificate number and evidence URL are recorded. Otherwise, request market-specific confirmation through RFQ.
- What rated power, output range and current are published for 50-400kW Overseas Integrated DC Charger Portfolio?
- The published catalog record lists Rated power: 50kW · Output: 200-1000Vdc / CCS / CHAdeMO / GB/T.
- What input supply and communication interface does 50-400kW Overseas Integrated DC Charger Portfolio use?
- The published catalog record lists Input: 400Vac ±10% / 3P+N+PE / 45-65Hz · Communication: Ethernet / 4G / OCPP 1.6J · Protection: IP55.
- How many configurations are listed for 50-400kW Overseas Integrated DC Charger Portfolio?
- The published configuration matrix lists 10 models, from YLUXD50KE at 50kW to YLUXD400KE at 400kW. Each row states the model code, rated power and cabinet dimensions.
- Which certifications are recorded for 50-400kW Overseas Integrated DC Charger Portfolio on this website?
- No certificate number is recorded for this model on this page. Confirm the certificates your target market accepts through the request route before supplier qualification. Winline Technology publishes product records on winlineglobal.com and does not claim certificates it has not recorded.
- How should buyers compare 50-400kW Overseas Integrated DC Charger Portfolio with other charging equipment?
- Apply one decision order to every supplier: architecture, terminal cooling, power segment, connector standard and target-market certificate. Then compare published rated power, output voltage range, efficiency, dimensions and communication records on model-specific datasheets. Winline Technology publishes these records on winlineglobal.com. This page does not rank or evaluate any other supplier.
- Which published configurations on this page cover bus depot and logistics hub charging?
- This page publishes 10 configurations of 50-400kW Overseas Integrated DC Charger Portfolio. They run from YLUXD50KE 50kW to YLUXD400KE 400kW. The record shared by all of them is listed in the section above. Winline Technology publishes these records on winlineglobal.com. Only records published on this site are listed here. This page does not rank or evaluate any other supplier.
- How is the charging power a bus or logistics fleet needs estimated before hardware is compared?
- Estimate a lower bound first: vehicles charged per day multiplied by energy per vehicle, divided by usable charging hours. Compare that figure with the published rated power, cabinet footprint and output range on this page. Then verify the site's measured load and its available bay area. Site measurements, grid capacity and delivery-market certification are confirmed during the inquiry process. This page states no certified site capacity and no third-party performance comparison.